Hybrid Inverter | 5000W | 48VDC | 220Vac/230Vac/240Vac | Feed power into the grid
GRANKIA GHS5K 48v single phase pure sine wave hybrid inverter 5kw is a flexible and intelligent hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power, also feed backup power into the grid.
It’s a simple and smart solar power storage system for home users to either store energy into battery and wait for night time usage or use for self-consumption first depending on demands. Priority for power source can be programmed and set up through SolarPower monitoring software.
GHS5K 48v hybrid inverter 5kw can realize self-consumption and feed-in to the grid from solar energy with best solution according to your setting. During the daytime solar power can run your home appliances and if there is extra solar power it will feed-in to the grid or you can choose to save them on the battery to backup when power failure or night time.
In comparison with conventional grid-tie inverter, hybrid solar inverter is able to not only feed-in power to grid but also store solar power to battery for future usage and directly power to the loads.
Hybrid Bi-directional pv inverter can save money by using battery energy first when PV energy is low. Until battery energy is low, will extract AC power from the grid.
GHS hybrid Bi-directional pv inverter can operate as an off-grid inverter to provide continuous power even without the grid. It’s perfect power solution for remote regions or temporary AC power source such as camping or flea market.
1.LCD display 9.PV connectors
2.Status indicator 10.Battery connectors
3.Charging indicator 11.Circuitbreaker
4.Fault indicator 12.Parallel communication cable
5.Function buttons 13.Current sharing cable
6.Power on/off switch 14.Dry contact
7.Grid connectors 15. RS-232 communication port
8.AC output connectors 16. USB communication port
The capacity of the inverter here means that the maximum power limit demand to which it can operate and provide electricity. Ideally, inverters between 756-1000 W are best suited for homes.
Keep the cables between your inverter and batteries as short as possible. This will help your batteries perform their best and keep the unit’s signal clean. The cables that come with the inverter are “rated” or good for up to six ft. If you plan on going over six ft., drop down to a larger gauge cable. Please call us if you are still unsure. This is pretty important stuff that should NOT be overlooked. If the cables between your battery and inverter get hot while under heavy load, then you should use heavier cables.
Buying an inverter can go a long way in helping you overcome the hardship you go through every time there is a power failure. Whether you need an inverter for your home or your office, you will get to choose from many different brands and models as per your budget.
Model | GHS5K |
PHASE | 1-phase in/1-phase out |
Max. PV INPUT POWER | 5000W |
Rated Output Power | 5000W |
Maximum Charging Power | 5000W |
Parallel Function | up to 9 units |
Dimension, D x W x H (mm) | 120 x 295 x 468 |
Net weight (kgs) | 12 |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 360VDC / 450VDC |
Start-up Voltage/Initial Feeding Voltage | 130VDC / 150VDC |
MPP Voltage Range | 120VDC~430VDC |
Number of MPP Trackers / Maximum Input Current | 1/1x18A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 220/230/240VAC |
Output Voltage Range | 184 -264.5VAC or 195.5 -253VAC(selectable) |
Nominal Output Current | 21.7A |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC start-up Voltage/ Auto Restart Voltage | 120VAC -140VAC / 180VAC |
Acceptable Input Voltage Range | 90VAC – 280VAC or 170VAC – 280VAC |
Max. AC Input Current | 40A |
PV INPUT (DC) | |
Max. DC Voltage | 450VDC |
MPP Voltage Range | 120VDC~430VDC |
Number of MPP Trackers/Max. Input Current | 1/1x18A |
BATTERY Mode Output (AC) | |
Nominal Output Voltage | 220/230/240VAC |
Output Waveform | Pure Sine Wave |
Efficiency (DC to AC) | 93% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 360VDC / 450VDC |
Start-up Voltage/Initial Feeding Voltage | 130VDC / 150VDC |
MPP Voltage Range | 120VDC~430VDC |
Number of MPP Trackers/Max. Input Current | 1/1x18A |
GRID OUTOUT (AC) | |
Nominal Output Voltage | 220/230/240VAC |
Output Voltage Range | 184 -264.5VAC or 195.5 -253VAC(selectable) |
Nominal Output Current | 21.7A |
AC INPUT | |
AC Start-up Voltage/Auto Restart Voltage | 120VAC – 140VAC /180VAC |
Acceptable Input Voltage Range | 90VAC – 280VAC or 170VAC – 280VAC |
Max. AC Input Current | 40A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 220/230/240VAC |
Efficiency (DC to AC) | 93% |
BATTERY& CHARGER | |
Nominal DC Voltage | 48 VDC |
Max. Charging Current | 100A |
Max. Solar Charging Current | 100A |
Max. AC Charging Current | 100A |
INTERFACE | |
Communication Port | RS-232,USB, Dry contact |
ENVIRONMENT | |
Humidity | 0~90% RH (Non-condensing) |
Operating Temperature | -10°C to 55 °C |
Altitude | 0-1000 m** |
*These figures may vary depending on different AC voltage and country requirements.
**Power derating 1% every 100m when altitude is over 1000m.