FG70-12 12v 70ah agm deep cycle battery for alarm system

VRLA Battery 12V 70AH | Dimension: 350x167x178x178mm

SKU: FG70-12 Category:

GRANKIA FG70-12 12v 70ah agm deep cycle battery for alarm system offers excellent performance in a wide range of applications including security and fire systems, medical devices, emergency lighting and UPS systems.

Flame Retardant ABS case and cover to UL 94 V-O for superior performance. Proven VRLA Absorbent Glass Mat (AGM) Technology that guarantees safe operation without maintenance and “non-restricted article” status for transportation.

Valve regulated sealed lead acid 12v 70ah agm deep cycle battery charges up to two times faster than conventional alternatives. No need for checking Electrolyte level and topping throughout its life. Sealed construction Ensures no leakage of Electrolyte from Terminal or casing.

FG70-12 12v 70ah agm deep cycle battery for alarm system

FG70-12 12v 70ah agm deep cycle battery for alarm system

AGM Deep Cycle Battery Features

  • TTP technique, to reduce internal resistance
  • Capable of high discharge rates.
  • No spills, no leaks, and no water to check
  • Long service life in float or cyclic applications
  • Absorbed Glass Mat technology (great durability and vibration-resistance)
  • High purity raw material
  • Maintenance-free
  • ABS Containers (UL94HB or UL94V0)
  • Minimal self-discharge – ideal for seasonal use

Lead Acid Battery Applications

  • Uninterrupted power supply(UPS)
  • Automotive and traction applications
  • Lighting equipment, fire alarms and security systems
  • Communication and telecom system
  • Solar energy system
  • High current drain applications
  • Fire alarms and security systems
  • Portable VTR/TV, tape recorders, radios, etc.
  • Various power toys and recreational equipment
  • Emergency power supplies in power generation plants and substations
  • Golf Cart

Sealed Battery Details

sealed lead acid battery 12v copper terminalReliable and high performance lead acid battery

AGM lead acid battery in series or in parallel connection

VRLA Battery Characteristics

Lead Acid Battery Discharge Characteristics Lead Acid Battery Charging Characteristics
Lead acid battery effect of temperature on capacity Lead acid battery self discharge characteristics
Lead acid battery relationship for open circuit voltage and residual capacity Lead acid battery the relationship for charging voltage and temperature
Lead acid battery floating life on temperature Lead acid battery cycle life on DOD

Deep Cycle Battery FAQ

  1. What does AGM mean on a deep cycle battery?

    Absorbent glass mat (AGM) is a class of lead-acid deep cycle battery in which the electrolyte absorbs into a fiberglass mat. The plates in an AGM battery may be flat like wet cell lead-acid battery, or they may be wound in a tight spiral.

  2. How do I know if my deep cycle battery is AGM?

    Basically, an AGM battery will always have a flat top, and only the negative and positive terminals of the battery will be sticking out. On the other hand, the liquid acid batteries have a removable top which is not the case with AGM batteries as they are properly sealed.

  3. When should I charge my deep cycle battery?

    They should be recharged when they indicate a 50% charge, but never let them get lower than 20% to ensure a long life. Lead-acid batteries, such as deep cycle batteries, run the risk of sulfation if left uncharged for too long.

 

The Articles You may Like

Nominal Voltage 12V(6 cells per unit)
Design Floating Life @25℃ 10 Years
Nominal Capacity @25℃(10 hour rate@7.00A,10.80V) 70Ah
Capacity @25℃ 20 hour rate (3.75A,10.5V) 75.0Ah
 5 hour rate (12.3A,10.5V) 61.5Ah
1 hour rate (44.7A,9.6V) 44.7Ah
Internal Resistance Full Charged Battery@25℃ ≤6.5mΩ
Ambient Temperature Discharge -20℃~50℃
Charge -20℃~50℃
Storage -20℃~50℃
Max. Discharge Current@25℃ 700A(5s)
Capacity affected by Temperature

(10 hr Capacity )

40℃ 102%
25℃ 100%
0℃ 85%
-15℃ 65%
Self-Discharge@25℃ per Month 3%
Charge (Constant Voltage) @25℃ Standby Use Initial Charging Current Less than 17.5A

Voltage 13.6-13.8V

Cycle Use Initial Charging Current Less than 17.5A

Voltage 14.4-14.9V

 

Discharge Constant Current per Cell (Amperes at 25°C)

F.V/Time 15min 30min 45min 1h 2h 3h 5h 6h 8h 10h 20h
1.60V 126.4 74.4 56.4 44.7 26.3 19.3 13.0 11.3 8.9 7.4 3.89
1.67V 119.4 70.5 54.2 43.3 25.4 18.7 12.8 11.1 8.8 7.2 3.85
1.70V 112.1 68.5 52.2 41.7 24.7 18.2 12.5 10.9 8.7 7.1 3.79
1.75V 105.0 65.5 49.9 40.0 24.1 17.8 12.3 10.7 8.5 7.1 3.75
1.80V 98.5 63.1 48.1 38.6 23.2 17.2 12.0 10.5 8.4 7.0 3.71

 

Discharge Constant Powerper Cell (Watts at25°C)

F.V/Time 15min 30min 45min 1h 2h 3h 5h 6h 8h 10h 20h
1.60V 241.6 147.8 107.0 85.7 49.8 36.9 25.1 21.9 17.4 14.4 7.7
1.67V 231.1 138.5 103.4 83.4 48.4 35.9 24.7 21.6 17.2 14.2 7.6
1.70V 215.4 135.5 100.1 80.5 47.3 35.1 24.4 21.3 17.0 14.1 7.5
1.75V 202.1 129.0 96.1 77.6 46.2 34.4 24.0 20.9 16.8 13.9 7.5
1.80V 189.7 123.8 92.9 75.0 44.7 33.4 23.5 20.6 16.6 13.9 7.4