Hybrid Inverter | 10KW | 48VDC | 380Vac/400Vac/415Vac | Feed power into the grid
GRANKIA GHS10K 48v mppt hybrid 3 phase solar inverter charger 10kw combines solar system, AC utility, and battery power source to supply continuous power. It is self-consumption and feed power into the grid.
It’s a simple and smart solar power storage system for home users to either store energy into battery and wait for night time usage or use for self-consumption first depending on demands. Priority for power source can be programmed and set up through SolarPower monitoring software.
Hybrid 3 phase solar inverter 10kw is primarily used for grid-tie (selling back to the utility company) purposes, but they can also provide backup power to your home when the electric utility fails.
In comparison with conventional grid-tie inverter, hybrid 3 phase solar inverter charger 10kw is able to not only feed-in power to grid but also store solar power to battery for future usage and directly power to the loads.
Hybrid Bi-directional pv inverter can save money by using battery energy first when PV energy is low. Until battery energy is low, will extract AC power from the grid.
1. PV connectors 10. Operation buttons
2. AC Grid connectors 11. Dry contact
3. Battery connectors 12. Battery thermal sensor
4. AC output connectors 13. EPO
5. RS-232 communication port 14. AC circuit breaker
6. USB communication port 15. DC Switch
7. Intelligent slot 16. Relay control port
8. Grounding 17. Parallel communication port
9. LCD display panel 18. Current sharing port
A hybrid solar inverter is the combination of a solar inverter and a battery inverter into a single piece of equipment that can intelligently manage power from your solar panels, solar batteries, and the utility grid at the same time.
A hybrid solar inverter can work without batteries. This type of system is attached to solar panels and to the power grid which supplies power from both.
If the power system is going to use AC loads, 120 (110-130) or 230 (208-240) Vac, then a hybrid inverter is important. Since it can work completely off the grid, can sometimes work with or without batteries, and even with or without solar panels a hybrid inverter is a very flexible solution.
Model | GHS10K |
PHASE | 3-phase in/3-phase out |
Max. PV INPUT POWER | 14850W |
Rated Output Power | 10000W |
Maximum Charging Power | 9600W |
Dimension, D x W x H (mm) | 168 x 500 x 622 |
Net weight (kgs) | 40 |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720VDC/900VDC |
Start-up Voltage/Initial Feeding Voltage | 320VDC/350VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400VAC (P-P) |
Output Voltage Range | 184VAC – 265VAC* per phase |
Nominal Output Current | 14.5A per phase |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 96% |
European Efficiency@Vnominal | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC start-up Voltage / Auto Restart Voltage | 120VAC – 140VAC per phase/180 VAC per phase |
Acceptable Input Voltage Range | 170VAC – 280VAC per phase |
Max. AC Input Current | 40A |
PV INPUT (DC) | |
Max. DC Voltage | 900VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
BATTERY Mode Output (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC (P-P) |
Output Waveform | Pure Sine Wave |
Efficiency (DC to AC) | 91% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720VDC / 900VDC |
Start-up Voltage/Initial Feeding Voltage | 320VDC / 350VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
GRID OUTOUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184VAC – 264.5 VAC* per phase |
Nominal Output Current | 14.5A per phase |
AC INPUT | |
AC Start-up Voltage/Auto Restart Voltage | 120VAC -140VAC per phase/ 180 VAC per phase |
Acceptable Input Voltage Range | 170VAC – 280VAC per phase |
Max. AC Input Current | 40A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC(P-P) |
Efficiency (DC to AC) | 91% |
BATTERY& CHARGER | |
Nominal DC Voltage | 48VDC |
Max. Charging Current | Default 60A, 10A-200A (Adjustable) |
INTERFACE | |
Communication Port | RS-232/USB and CAN Interface |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0~90% RH (Non-condensing) |
Operating Temperature | -10 to 55 °C |
Altitude | 0-1000 m** |
*These figures may vary depending on different AC voltage and country requirements.
**Power derating 1% every 100m when altitude is over 1000m.